Flow Measurement




Coriolis Mass Flow Meter 

  • 4 … 20 mA current / HART 7.1 output
  •  current output in the event of an alarm can be configured to 21 … 23 mA (NAMUR NE43).
  •  Measuring range: Can be configured between 0.1 … 1 x QmaxDN
  •  Two slots for optional plug-in cards for retrofitting additional current / digital outputs or a digital input.
  •  Parameterization by means of HART communication.
  •  Response time ≥ 1 s, 0 … 99 % as step function (corresponds to 5 τ).
  •  Damping: 0.2 … 100 s configurable (1 τ).
  •  Low flow cut-off: 0 … 5 % for current and pulse output.

Electromagnetic Flow Meter

  • Versatile and simple configuration
    – Through glass configuration eliminating the need to remove the cover and reducing commissioning time
    – Soft key based functionality
    – “Easy Set-up” function
  • State-of-the-art memory technology( Data storage enables transmitter exchange without the need for reconfiguration)
  • Diagnostics for real-life-situations
    – Simplified plant trouble shooting
    – Status messages in accordance with NAMUR
    – Help texts in LCD display
  • ScanMaster in situ verification software option( Allows the customer to perform in situ verification of the flowmeter and the plant)

Multiphase Flowmeter

  • Continuous, real-time measurement
  • Radioactive-free
  • Based on conventional instrumentation
  • 80 to 100% GVF operating range
  • Self-calibrating
  • Proprietary software
  • Field mounted or remote (for example, control room) user interface

Primary Flow Differential meter.

  • SolveDP enables the sizing of ABB’s entire DP product portfolio using a single software package. In addition to sizing, the software has the capability to generate ordering codes.  It is licensed software but the cost of a licence is yet to be released.
  • Using the licence key supplied and a live internet connection, it also automatically regularly checks for software updates, ensuring that the user’s version of the software is always up-to-date.

Variable Area Flow meter.

  • Application(Clean, low viscosity liquids and gases)
  • Mounting(Vertically, in line or wall mouted)
  • Connections- 1/4 to 1 in., threaded, vertical or horizontal
  • Flow ranges– Water flows: 1 to 3000 l/h
  • Flow turndown– Typically 10:1
  • Operating pressure – Up to 100 bar (1450 lbf/in 2 g)
  • Operating temperature – Up to 180 °C (356 °F)
  • Tube material and float material– Stainless steel

Thermal Mass Flow Meter

  • Measuring media(Air, Nitrogen, Oxygen, Carbon dioxide, Methane, Hydrogen, Natural Gas, Biogas, Helium, Argon, Propane, Ethane, Ethene, Butane, Ammonia, more gas types on request).
  • Integral mount transmitter design( single compartment transmitter housing)
  • Measuring medium temperature( -25 … 150 °C (-13 … 302 °F))
  • Ambient temperature( -20 … 70°C ( -4 … 158°F)).
    – optional -40 … 70 °C (-40 … 158 °F)
    – optional -50 … 70 °C (-58 … 158 °F)
  • Supply Voltage-24 V DC ±20 %

Swirl Flowmeter

  • Intuitive operation
    – Easy Set-up function
    – Clear text display
    – Meter configuration through the front glass with closed cover
  • Accuracy for liquids, gases and steam– +/- 0.5 % of rate
  • Process connection / meter sizes– Flange design / DN 15 to 400 (1/2 to 16 in.)
  • Approvals for explosion protection– ATEX, IECEx, cFMus, NEPSI
  • SIL2-certified in accordance with IEC 61508
  • Output / communication( 4 to 20 mA / HART 7,  Modbus RTU-RS485)
  • Optional binary output– For use as a limit switch, pulse output or frequency output
  • Optional input from field– Pressure, temperature, methane content, density gas analyzer

Vortex Flowmeter

  • Intuitive operation(Easy Set-up function, Clear text display,  Meter configuration through the front glass with closed cover)
  • Accuracy for liquids– +/- 0.65% of rate
  • Accuracy for gases and steam– +/- 0.9% of rate
  • Process connection / meter sizes
    – Flange-mount design / DN 15 to 300 (1/2 to 12 in.)
    – Wafer type design / DN 25 to 150 (1 to 6 in.)
  • Approvals for explosion protection– ATEX, IECEx, cFMus, NEPSI
  • SIL2-certified in accordance with IEC 61508.
  • Output / communication
    – 4 to 20 mA / HART 7
    – Modbus RTU-RS485
  • Optional input from field– Pressure, temperature, methane content, density gas analyzer.