Temperature Measurement




Cable Thermometers & Compact Thermometers

  • Heat and corrosion resistant sheath material of MI-cable for use in the temperature range of -196 up to 1100°C with RTD and TC sensors
  • Process connections for Plug-In, screw-In or Surface measurement
  • Electrical connection is possible with head type F, standard- or Lemo-plugs or different cables
  • Approvals for explosion protection
    – ATEX Ex ia
    – ATEX Ex ib
    – ATEX Ex n
    – IECEx ia

Field Mount Temperature Transmitter

  • Universal sensor input
  • Various sensor error-calibration possibilities
  • Sensor backup / automatic sensor redundancy switching (2 x Pt100 3-wire connection)
  • Output signal
    – 4 to 20 mA, HART
    – PROFIBUS PA 3.01
    – FOUNDATION Fieldbus ITK 5.2
  • Accuracy 0.1 %, long-term stability 0.05 % per year
  • Wire break / corrosion monitoring (NE89)
  • IP 66 / IP 67, NEMA 4X aluminum or stainless steel field-mount housing
  • Approvals for explosion protection
    – ATEX, IECEx, zone 0
    – FM / CSA
    – GOST

Head Mount Temperature Transmitter

  • Universal sensor input (RTD, thermocouple, Ω, mV)
  • Various sensor error-calibration possibilities(One point, two point)
  • Output signal( 4 to 20 mA, HART)
  • Accuracy 0.1 %, long-term stability 0.05 % per year.
  • Wire break / corrosion monitoring (NE89).
  • Extended diagnostics (NE107)
  • Approvals for explosion protection
    – ATEX, IECEx, zone 0
    – FM / CSA
    – GOST

High Temperature Thermometer

  • Supports numerous applications
    – In accordance with EN 50446 and also available in accordance with ABB standard
  • Connection heads
    – AUZ: Aluminum, with hinged cover
    – AUZH: Aluminum with upper hinged cover
    – BUZ: Aluminum, with hinged cover
    – BUZH: Aluminum, with upper hinged cover
    – Other heads in various forms and materials
    – Transmitter in connection head (4…20 mA HART, FF, PA)
  • Process connections
    – Stop flange with counterflange
    – threaded socket
    – welded standard flange

Multipoint Thermometers

  • Compact thermocouple for restricted access.
  • Flexible thermocouple for use in existing thermowell.
  • Guided tube thermocouple for replaceable sensors in operation.
  • Medusa thermocouple for individually routed thermocouple sensors.
  • Medusa RTD for individually routed RTD sensors.

Rail Mount Temperature Transmitter

  • Universal sensor input
    – RTD, thermocouple, Ω, mV
  • Various sensor error-calibration possibilities
    – One point, two point
  • Output signal
    – 4 to 20 mA, HART
  • Accuracy 0.1 %, long-term stability 0.05 % per year
  • Wire break / corrosion monitoring (NE89)
  • Extended diagnostics (NE107)
  • Approvals for explosion protection
    – ATEX, IECEx, zone 0
    – FM / CSA
    – GOST

Sanitary Application Thermometers

  • Temperature range
    – -50 to +250 °C (-58 to +482 °F)
  • Max. pressure
    – 10 bar / 140 bar (145 psi / 2030 psi)
  • Output signal
    – Sensorsignal, 4 to 20 mA ,HART
  • Response time
    – short … medium

Temperature Cable & Wires

  • Mineral insulated cables have an outer sheath of metal with 2 to 8 inner conductors. The insulation material is made from a highly compressed metal-oxide powder (preferably MgO or Al2O3).
    Mineral insulated thermocouple cables have inner conductors of thermocouple base material. Mineral insulated cables for RTDs have inner conductors of copper, copper-nickel alloys, nickel, nickel-chromium or nickel-plated copper.
    Mineral insulated cables are designed for high-temperature applications and are used wherever there are particularly strict requirements with regard to mechanical, chemical and electrical stability.

Thermowells

  • Engineered to international standards
    – ISO19001:2000
  • Manufactured with full material control
    – 3.1 certification
    – Traceability to producing mill
    – X-Ray PMI available
  • Documented to Oil & Gas industry standards
    – Documents compiled on electronic media
    – Material certification
    – Welding certification
  • Applications
    – Oil & Gas downstream
    – Oil & Gas upstream
    – Arduous applications requiring high specification