Coriolis Mass Flow Meter
- 4 … 20 mA current / HART 7.1 output
- current output in the event of an alarm can be configured to 21 … 23 mA (NAMUR NE43).
- Measuring range: Can be configured between 0.1 … 1 x QmaxDN
- Two slots for optional plug-in cards for retrofitting additional current / digital outputs or a digital input.
- Parameterization by means of HART communication.
- Response time ≥ 1 s, 0 … 99 % as step function (corresponds to 5 τ).
- Damping: 0.2 … 100 s configurable (1 τ).
- Low flow cut-off: 0 … 5 % for current and pulse output.
Electromagnetic Flow Meter
- Versatile and simple configuration
– Through glass configuration eliminating the need to remove the cover and reducing commissioning time
– Soft key based functionality
– “Easy Set-up” function
- State-of-the-art memory technology( Data storage enables transmitter exchange without the need for reconfiguration)
- Diagnostics for real-life-situations
– Simplified plant trouble shooting
– Status messages in accordance with NAMUR
– Help texts in LCD display
- ScanMaster in situ verification software option( Allows the customer to perform in situ verification of the flowmeter and the plant)
– Through glass configuration eliminating the need to remove the cover and reducing commissioning time
– Soft key based functionality
– “Easy Set-up” function
– Simplified plant trouble shooting
– Status messages in accordance with NAMUR
– Help texts in LCD display
Multiphase Flowmeter
- Continuous, real-time measurement
- Radioactive-free
- Based on conventional instrumentation
- 80 to 100% GVF operating range
- Self-calibrating
- Proprietary software
- Field mounted or remote (for example, control room) user interface
Primary Flow Differential meter.
- SolveDP enables the sizing of ABB’s entire DP product portfolio using a single software package. In addition to sizing, the software has the capability to generate ordering codes. It is licensed software but the cost of a licence is yet to be released.
- Using the licence key supplied and a live internet connection, it also automatically regularly checks for software updates, ensuring that the user’s version of the software is always up-to-date.
Variable Area Flow meter.
- Application(Clean, low viscosity liquids and gases)
- Mounting(Vertically, in line or wall mouted)
- Connections- 1/4 to 1 in., threaded, vertical or horizontal
- Flow ranges– Water flows: 1 to 3000 l/h
- Flow turndown– Typically 10:1
- Operating pressure – Up to 100 bar (1450 lbf/in 2 g)
- Operating temperature – Up to 180 °C (356 °F)
- Tube material and float material– Stainless steel
Thermal Mass Flow Meter
- Measuring media(Air, Nitrogen, Oxygen, Carbon dioxide, Methane, Hydrogen, Natural Gas, Biogas, Helium, Argon, Propane, Ethane, Ethene, Butane, Ammonia, more gas types on request).
- Integral mount transmitter design( single compartment transmitter housing)
- Measuring medium temperature( -25 … 150 °C (-13 … 302 °F))
- Ambient temperature( -20 … 70°C ( -4 … 158°F)).
– optional -40 … 70 °C (-40 … 158 °F)
– optional -50 … 70 °C (-58 … 158 °F)
- Supply Voltage-24 V DC ±20 %
– optional -40 … 70 °C (-40 … 158 °F)
– optional -50 … 70 °C (-58 … 158 °F)
Swirl Flowmeter
- Intuitive operation
– Easy Set-up function
– Clear text display
– Meter configuration through the front glass with closed cover
- Accuracy for liquids, gases and steam– +/- 0.5 % of rate
- Process connection / meter sizes– Flange design / DN 15 to 400 (1/2 to 16 in.)
- Approvals for explosion protection– ATEX, IECEx, cFMus, NEPSI
- SIL2-certified in accordance with IEC 61508
- Output / communication( 4 to 20 mA / HART 7, Modbus RTU-RS485)
- Optional binary output– For use as a limit switch, pulse output or frequency output
- Optional input from field– Pressure, temperature, methane content, density gas analyzer
– Easy Set-up function
– Clear text display
– Meter configuration through the front glass with closed cover
Vortex Flowmeter
- Intuitive operation(Easy Set-up function, Clear text display, Meter configuration through the front glass with closed cover)
- Accuracy for liquids– +/- 0.65% of rate
- Accuracy for gases and steam– +/- 0.9% of rate
- Process connection / meter sizes
– Flange-mount design / DN 15 to 300 (1/2 to 12 in.)
– Wafer type design / DN 25 to 150 (1 to 6 in.)
- Approvals for explosion protection– ATEX, IECEx, cFMus, NEPSI
- SIL2-certified in accordance with IEC 61508.
- Output / communication
– 4 to 20 mA / HART 7
– Modbus RTU-RS485
- Optional input from field– Pressure, temperature, methane content, density gas analyzer.
– Flange-mount design / DN 15 to 300 (1/2 to 12 in.)
– Wafer type design / DN 25 to 150 (1 to 6 in.)
– 4 to 20 mA / HART 7
– Modbus RTU-RS485